For those that have a Doug Hall Electronics Model RBI-1 frequency agile multi port remote base and wish to use it on app_rpt / AllStar system. | For those that have a Doug Hall Electronics Model RBI-1 frequency agile multi port remote base and wish to use it on app_rpt / AllStar system. | ||
This was originally created for direct use in a PC that has a parallel port for signaling the device. There is no other method built into the software. | This was originally created for direct use in a PC that has a parallel port for signaling the device. There is no other method built into the app_rpt software. | ||
It uses the first 3 pins of the parallel port and can not be changed. So if you have been using the pins for anything else, you will need to migrate them to higher pins than the first 3. | It uses the first 3 pins of the parallel port and can not be changed. So if you have been using the pins for anything else, you will need to migrate them to higher pins than the first 3. | ||
Line 17: | Line 14: | ||
No buffering is required attaching this to the RBI-1's DB9 interface on the correct PP pins. | No buffering is required attaching this to the RBI-1's DB9 interface on the correct PP pins. | ||
See data on Parallel Port GPIO: https://wiki.allstarlink.org/wiki/SimpleUSB_Channel_Driver#Parallel_Port | See data on Parallel Port GPIO: https://wiki.allstarlink.org/wiki/SimpleUSB_Channel_Driver#Parallel_Port | ||
Line 28: | Line 24: | ||
iobase=0x378 ;(for lpt1) | iobase=0x378 ;(for lpt1) | ||
remote=rbi ; Doug Hall RBI-1 | remote=rbi ; Doug Hall RBI-1 | ||
functions=funtions-remote29285 ; Function list from link - use your node number | functions=funtions-remote29285 ; Function list from link (a list of agile working commands) - use your node number | ||
memory=memory29285 ; system stored radio presets, not required - use your node number | memory=memory29285 ; 'system stored' radio presets, not required - use your node number | ||
Line 57: | Line 53: | ||
;Not Required but noted: | ;Not Required but noted: | ||
[memory29285] ;stored presets for radio, format: Freq | [memory29285] ;stored presets for radio, format: (recall# xx) = (Freq 6 digits and decimal) (TX PL Tone ) ( CTCSS Tone ) (ofset + - S ) ( power l m h ) | ||
init=224.660,100.0,-l ;initial freq/mode on start-up/boot - choose something safe in case of error | init=224.660,100.0,-l ;initial freq/mode on start-up/boot - choose something safe in case of error. Not required. Can be remarked out. | ||
00=224. | 00=224.560,100.0,-l | ||
01=224.460,114.8,-l | 01=224.460,114.8,-l | ||
02=224.580,131.8,-l | 02=224.580,131.8,-l | ||
03=223.980,100.0,-l | 03=223.980,100.0,-l | ||
04=146.940,114.8,-lt | |||
10=442.175,162.2,+l | |||
11=444.475,114.8,+l | |||
12=444.150,100.0,+l | |||
;13=446.500,100.0,sl | ;13=446.500,100.0,sl | ||
; Tuning a agile remote base has a unchangeable prefix of (star 5) *5 | |||
Note : | |||
It is more than convenient and desirable to put all of the control functions on a published node and secure the node/audio on a private node you can disconnect. | It is more than convenient and desirable to put all of the control functions on a published node and secure the node/audio on a private node you can disconnect. | ||
This makes it dis-connectable for periodic use and prevents you from the need to connect to the node in 'command mode' ie *4xxxxx to control it's agile interface. | This makes it dis-connectable for periodic use and prevents you from the need to connect to the node in 'command mode' ie *4xxxxx to control it's agile interface. | ||
That can allow you to set it before connecting the node for audio as well. | |||
Always review and test macro/scheduler initiations of this before leaving it to run from it unattended. | |||
There is a security log-in function for remote base control -*To be added to the wiki in a section for all remote base* - |
Revision as of 00:56, 4 February 2021
For those that have a Doug Hall Electronics Model RBI-1 frequency agile multi port remote base and wish to use it on app_rpt / AllStar system.
This was originally created for direct use in a PC that has a parallel port for signaling the device. There is no other method built into the app_rpt software.
It uses the first 3 pins of the parallel port and can not be changed. So if you have been using the pins for anything else, you will need to migrate them to higher pins than the first 3.
PP1 = data
PP2 = clock
PP3 = reset
No buffering is required attaching this to the RBI-1's DB9 interface on the correct PP pins.
See data on Parallel Port GPIO: https://wiki.allstarlink.org/wiki/SimpleUSB_Channel_Driver#Parallel_Port
Set-up inside app_rpt:
In Rpt.conf you will need to set lines in the nodes stanza:
iobase=0x378 ;(for lpt1) remote=rbi ; Doug Hall RBI-1 functions=funtions-remote29285 ; Function list from link (a list of agile working commands) - use your node number memory=memory29285 ; 'system stored' radio presets, not required - use your node number
- Remote Commands
[funtions-remote29285] ;for rbi-1 use your node number
0=remote,1 ; Retrieve Radio Stored Memory Channel 1=remote,2 ; Set freq. VFO MMMMM*KKK*O (Mhz digits, Khz digits, Offset) 2=remote,3 ; Set tx PL tone PL Tone HHH*D* 3=remote,4 ; Set rx PL tone HHH*D*
40=remote,100 ; Rx PL off 41=remote,101 ; Rx PL on 42=remote,102 ; Tx PL off 43=remote,103 ; Tx PL on 44=remote,104 ; Low Power 45=remote,105 ; Medium Power 46=remote,106 ; High Power
51=remote,5 ; Long status query 52=remote,140 ; Short status query 67=remote,210 ; Send a * 69=remote,211 ; Send a #
- Not Required but noted
[memory29285] ;stored presets for radio, format: (recall# xx) = (Freq 6 digits and decimal) (TX PL Tone ) ( CTCSS Tone ) (ofset + - S ) ( power l m h )
init=224.660,100.0,-l ;initial freq/mode on start-up/boot - choose something safe in case of error. Not required. Can be remarked out.
00=224.560,100.0,-l 01=224.460,114.8,-l 02=224.580,131.8,-l 03=223.980,100.0,-l 04=146.940,114.8,-lt 10=442.175,162.2,+l 11=444.475,114.8,+l 12=444.150,100.0,+l
- 13=446.500,100.0,sl
- Tuning a agile remote base has a unchangeable prefix of (star 5) *5
Note : It is more than convenient and desirable to put all of the control functions on a published node and secure the node/audio on a private node you can disconnect. This makes it dis-connectable for periodic use and prevents you from the need to connect to the node in 'command mode' ie *4xxxxx to control it's agile interface. That can allow you to set it before connecting the node for audio as well. Always review and test macro/scheduler initiations of this before leaving it to run from it unattended.
There is a security log-in function for remote base control -*To be added to the wiki in a section for all remote base* -